MP8000 Series

Bluetooth Overload Relay

We're here to help

Talk to an expert today.
Our friendly team of highly trained specialists will quickly assist you.

Get a quote technical support 1300 387 326

Description

The MP8000 is an advanced motor protection electronic overload relay that is fully programmable via Bluetooth using the Littelfuse app on an Android or iPhone mobile device. It is easy to use and arc-flash safety is increased because the app allows settings to be modified and real-time operational information viewed. Viewing operational information and faults on the app does not require the user to open the control panel.

The MP8000 protects any motor drawing 0.5-1,000 full load Amps (external CTs are required above 100 amperes). It is designed for single or 3-phase systems with operating voltages of 90-690 VAC (use of external potential transformers can extend upper voltage range above 690 VAC). Common applications include conveyor systems, HVAC equipment, saws and grinders, fan motors, and almost any pumping application.

Protection is unsurpassed by combining overload, voltage, phase loss and reversal, voltage and current unbalance, power monitoring, and underload in one package. For standalone applications, the Bluetooth interface can be used when paired with a smartphone or tablet. The units also feature an Ethernet communications port that can be used to form an Ethernet Modbus TCP/IP network or Ethernet/IP. Units can be remotely monitored and controlled from a PC, or SCADA system, and data logging through a PC with the optional Solutions software or other software program using the MP8000 memory map. This capability allows for a simple cost-effective way to further enhance arc-flash safety.


Features & Benefits

  • Bluetooth interface

    Visual indication for programming, viewing real-time voltage or current, and last fault information (date and time stamped)

  • Programmable voltage and current setting

    Allows usage on wide range of systems

  • 3 selectable restart options

    Choose from automatic, semi-automatic, or manual to best meet individual application needs

  • 4 programmable delay timers

    Program separate delay times for power up, rapid cycle protection, motor cool down, and underload restarting

  • Flexible reset

    Reset can be done through pushbutton on panel, remotely via the network

  • Network communications capability 

    Compatible with Ethernet Modbus TCP/IP and Ethernet/IP

Advanced Features 

  • Overload/Overpower (49)
  • Underload/Underpower (37P)
  • Overcurrent (51)/Jam
  • Undercurrent (37)
  • Current Unbalance/Phase Loss (46)
  • Phase Reversal (47)
  • Overvoltage (59)
  • Undervoltage (27)
  • Voltage Unbalance (47)
  • Rapid Cycling/Jog
  • Contactor Failure
  • Zero-Sequence Ground Fault (50Ns)
  • PTC Motor Overtemperature (49)


MP8000 Datasheet

MP8000 FAQ

MP8000 Manual

MP8000 Quick Start Guide

Specifications

Functional Characteristics

  • Frequency: 50/60Hz
  • TC- Overcurrent Trip Class: Trip class 02-60 or linear

Output Characteristics

Output Contact Rating

  • Control relay: SPST - Form A
  • Auxiliary relay: SPDT - Form C
  • Pilot Duty Rating: B300
  • General Purpose: 5A @ 240VAC

General Characteristics

Ambient Temperature Range

  • Operating: -40° to 70°C (-40° to 158°F)
  • Storage: -40° to 85°C (-40° to 185°F)

Accuracy

  • Voltage: ±1% of reading ±0.5 V
  • Current: ±2% (2 to 100 amperes direct)
  • Timing: +/-0.5% of setting +/- 1second
  • GF Current: ±5%

Repeatability

  • Voltage: ±0.5%
  • Current: ±1% (2 to 100 A direct)
  • Power Consumption: <5 W
  • Pollution Degree: 3 (conformal coating standard)
  • Class of Protection: IP20
  • Relative Humidity: 10-95%, non-condensing per IEC 68-2-3
  • Terminal Torque (depluggable terminal blocks): 5.5 in.-lbs.
  • Terminal Torque (Earth Ground): 7.9 in.-lbs.

Standards Passed

  • Electrostatic Discharge (ESD): IEC 61000-4-2, Level 3, 6kV contact, 8kV air
  • Radio Frequency Immunity (RFI), Conducted: IEC 61000-4-6, Level 3 10V/m
  • Radio Frequency Immunity (RFI), Radiated: IEC 61000-4-3, Level 3 10V/m
  • Fast Transient Burst: IEC 61000-4-4, Level 3, 3.5kV input power
  • Surge: IEC 61000-4-5, Level 3, 2kV line-to-line; Level 4, 4kV line-to-ground
  • FCC Rating: Part 15.107 for emissions, Part 15.247 for intentional radiators
  • Short Circuit Withstand Rating: 100kA symmetrical at 690VAC
  • Hi-Potential Test: Meets UL508 (2 x rated V +1000V for 1 minute)

Safety Marks

  • cULus: UL60947, UL1053, C22.2 (File #E68520)
  • CE: IEC 60947 Edition 5.2, IEC 60947-8
  • Maximum Conductor Size (with insulation): 0.63”
  • Dimensions: H 74.42 mm (2.93”); W 103.63 mm (4.08”); D 121.67 mm (4.79”)
  • Weight: 0.85 lbs (13.6 oz, 385.6 g)
  • Mounting Method: Surface mount (4 - #8 screws) or DIN-rail mount


Ordering Information

MODELLINE VOLTAGEMOTOR FULL AMP RANGEDESCRIPTION
MP800090-690VAC
(use of external potential transformers can extend upper voltage range above 690VAC)
0.5-1,000A+ (external CTs required above 100A)Provides remote wired communication via Ethernet Modbus TCP/IP or Ethernet/IP



Accessories

ZSCT Series Current Transformer
Used with Littelfuse relays to detect low levels of earth-leakage current.

VIDEO

Top FAQs

The MP8000 has a wide voltage and current range and operates on 50/60 Hz to protect any motor or pump.

It can also be used to retrofit older current-only based electronic overloads.

It can operate between 90-690VAC and 0.5-1,000A.

Traditional relays require the user to open the electrical cabinets (where relays are typically installed) panel door to use the relay, whether it’s to modify the settings, or to review the cause of a trip event. 

Opening the panel door exposes the worker to shock hazards. Bluetooth, however, enables remote access to these settings, metering and data log information which prevents personnel from unnecessarily having to open the door, thus less exposure to risks.

  • Overload (Overpower) (49)
  • Underload (Underpower) (37P)
  • Overcurrent (51)/Jam
  • Undercurrent (37)
  • Current Unbalance/Phase Loss (46)
  • Phase Reversal (47)
  • Overvoltage (59)
  • Undervoltage (27)
  • Voltage Unbalance (47)
  • Rapid Cycling/Jog
  • Contactor Failure
  • Zero-Sequence Ground Fault (50Ns)
  • PTC Motor Overtemperature (49)

The MP8000 can be used in both single phase and 3 phase applications.

Yes, the MP8000 can be put into current-only mode which will disable voltage-based protection functions. However, Littelfuse strongly recommends utilizing the voltage-based protection functions for superior protection especially prior to motor startup.

The current-only mode is intended for retrofit applications on voltages above 690 VAC.


The MP8000 can be surface or panel mounted, or installed on a DIN rail.

No, the MP8000 uses Bluetooth to connect to your smart phone or tablet via the Littelfuse app, This enhances the users safety as it allows remote access.

Yes, you can access the information remotely through the Littelfuse MP8000 PC software or through other software programs communicating with the MP8000 through the Ethernet interface. Contact Fuseco for information on how to download this software.



We're here to help

Talk to an expert today.
Our friendly team of highly trained specialists will quickly assist you.

Get a quote technical support 1300 387 326

We promise to respond within 4 business hours (AEST).

Or you will receive $100 off your next purchase. Read how it works.

Protection Relays

Littelfuse Protection Relay and Arc-Flash FAQ
Littelfuse White Paper -Key Considerations for selecting-Arc-Flash
Littelfuse Protection Relays AF0100 Generator Application Guide
Littelfuse PGR-8800 Application Guide
Littelfuse AF-0500 Application Guide
Littelfuse Diagram -Protect Your Wind Turbine From Arc-Flash hazards
A new approach to mining earth leakage protection with medium voltage drives

Hi Tim, just wanted to thank you and the Fuseco team for your help. You've managed to help us solve some nagging issues here and the Littelfuse SE-330AU relay installation has saved us a lot of time. Thanks!

Mark Sherman

PGS Silver, Queensland

Just wanted to send a note of thanks to you guys. When it comes to relays, your advice & service is high level & appreciated. Cheers.

Jesse Marshall

Newcrest WA

The Littelfuse SE-701 & the CT's are functioning well. Thanks guys, really appreciate your help. Good to work with people you can rely on.

Cliff Peligro

Alpha Coal, Queensland

Technical Support

Our experts are all pre-eminent leaders in electrical products who provide excellent support in their areas of expertise.

Technical support

Talk to an expert

Our friendly team are highly trained product experts who really enjoy helping customers find what they need.

1300 387 326

call 1300 387 326

Enquire by email

We promise to respond within 4 business hours (AEST) or you will receive $100 off your next purchase.

Enquire now