loader

Loading...Please wait.

Active Filters

Active Filters
Sinexcel_webpage2.jpg


Fuseco is proud to announce that Sinexcel Active Harmonic Filters are now available in Australia. With their unique modular design and 3-level topology performance, Sinexcel Active Harmonic Filters offer a highly flexible, reliable and customisable solution in active harmonic compensation systems. Finally a solution exists that offers new generation technology and high performance in such a compact and light weight box.




Make an Enquiry



Brochure

View Product List 


Key features


Compact Size and Light Weight
Can be wall mounted and installed in small spaces.

Harmonics Compensation Capability
Compensates 2nd to 50th harmonic order or simultaneous compensation of all 50 harmonic orders.

Algorithm Intelligence
Intelligent technology that integrates both FFT and Dynamic Compensation Modes, customized to client’s requirements.

3-Level Topology
Unique 3-level topology based on a zero voltage transformation design & incorporating a high frequency inductor technology results in more than 97% efficiency.

Ease of Installation and Commissioning
(‘Plug and Play’)

User-friendly Interface and Monitoring
Very easy to operate. Online monitoring and programming available. Presents information in terms of numerical data, waveform analysis, etc.

Also available in 690V

2 year warranty

Standards
IEC61000 / IEC60146 / EN55011 / EN50091 / IEEE519



Wall Mounted Active Filter

Wall Mounted Active Filter

Rack_Mounted.jpg

Rack Mounted Active Filter


> Examples of Installations 

> Contact Fuseco for more information

> Modular Active Harmonic Filters Brochure
 

> View Product List
 

General Specifications

Rated Compensation Current

25A-100A

100A-600A in parallel configuration format


Neutral Filtering Capability

Yes

Rated Voltage(V)

380VAC -40% to +20%

690V also available


IGBT Frequency

20KHz

Rated Frequency (Hz)

45-63


Self Protection

Yes

Harmonic Compensation Efficiency

>97%


Communication Interface

RS485, Ethernet

Harmonics Compensation Capability

THDi<5%


Communication Protocol

Modbus, TCP/IP

Harmonics Compensation Range

2nd to the 50th Harmonic Order


Operating Temperature

-5°C to +45°C

Response Time

<100μs


Relative Humidity

Max <95%, no condenstaion

Full Response Time

<10ms


Altitude

1500m, 1% power reduction for each additional 100m, between 1500m and 4000m


  Technical Specifications


Model

Sinexcel 25A

Sinexcel 35A

Sinexcel 50A

Sinexcel 60A

Sinexcel 100A

Rated compensation Current

25

35

50

60

100

Dimensions

(w x h x d, mm)

260x455x200

260x455x200

440x590x200

440X590X200

440X575X232

Net Weight (kg)

16

16

35

35

36

Mounting Type

Wall / Rack

Wall / Rack

Wall / Rack

Wall / Rack

Wall / Rack

Cooling Type

Smart Air Cooling 75L/Sec

Smart Air Cooling 75L/Sec

Smart Air Cooling 151L/Sec

Smart Air Cooling 151L/Sec

Smart Air Cooling 300L/Sec

Noise Level

<54dB

<54dB

<56dB

<56dB

<58dB

CT Rating

150/5-10,000/5

150/5-10,000/5

150/5-10,000/5

150/5-10,000/5

150/5-10,000/5

Protection Class

IP20

IP20

IP20

IP20

IP20



Model

Sinexcel 200A

Sinexcel 300A

Sinexcel 400A

Sinexcel 500A

Sinexcel 600A

Rated compensation Current

200A

300A

400A

500A

600A

Dimensions

(w x h x d, mm)

600X1000X2100

600X1000X2100

600X1000X2100

600X1000X2100

600X1000X2100

Net Weight (kg)

240

280

320

360

430

Mounting Type

Cabinet

Cabinet

Cabinet

Cabinet

Cabinet

Cooling Type

Intelligent Air Cooling    600L/Sec

Intelligent Air Cooling   900L/Sec

Intelligent Air Cooling 1200L/Sec

Intelligent Air Cooling 1500L/Sec

Intelligent Air Cooling 1500L/Sec

Noise Level

<54dB

<54dB

<56dB

<56dB

<58dB

CT Rating

150/5-10,000/5

150/5-10,000/5

150/5-10,000/5

150/5-10,000/5

150/5-10,000/5

Protection Class

IP20

IP20

IP20

IP20

IP20


Selection Guidelines


  • Suitable for use in 3-wire and 4-wire systems
  • For 3-wire systems configuration, 2 CT's are required (at L1&L3)
  • For 4-wire configuration, 3 CT's are required (at L1, L2 & L3)
  • The harmonic currents for compensation can be obtained from system measurement results or derived from calculations based      on the transformer and load data.